TPP540 UV Air Purifier User’s Manual

Air Purifiers

Thank you for purchasing the Therapure ® 540 air purifier. With UV protection and permanent HEPA-type filtration to purify the air, the Therapure ® 540 air purifier will greatly improve the quality of the air in your home, office or other environments. We want you to be fully
satisfied with your Therapure ® 540. That’s why your Therapure ® 540 comes with a one-year limited warranty.

Once you’ve experienced the purity of Therapure ® 540 air, visit us at our website to find out more ways to improve the quality of your air and your life with our premium products and upgrades.

Please be sure to read the following instructions carefully to ensure optimal performance and safety.

SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

WARNING: RISK OF ELECTRICAL SHOCK

Safety precautions should always be used when operating this or any electrical appliance. Decrease the risk of electrocution, electric shock, injury or fire by reading and following all the warnings below.

Use only as described in this Therapure® 540 manual. To reduce the risk of electric shock, do not attempt to service the product in any way other than in the manner described in the “Cleaning & Maintenance” section of this manual.

READ ALSO: IONIC PRO TURBO USER’S MANUAL

READ ALL INSTRUCTIONS BEFORE OPERATING THE AIR PURIFIER.

» This product operates at 120V AC, 60Hz only.
» Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it will not be tripped over.
» Do not operate the product in any greasy environment, such as in the kitchen. This product is not intended to filter oil or grease from the air.
» Do not use the Therapure® 540 air purifier in bathrooms or other humid environments. Do not use near fireplaces or in areas where flammable or combustible vapors or products may exist.
» Always unplug the power cord from the electrical outlet when the purifier is not in use, before cleaning, inserting or removing parts or before moving to another location.
» Never run the air purifier unless it is fully assembled.
» This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
» Always turn off all controls before unplugging the Therapure® 540 air purifier from the outlet.
» Attempting to service the Therapure® 540 air purifier in any way that is not described in this owner’s manual will cause the warranty to be voided and could cause serious personal injury to the user and/or result in considerable damage to the unit.
» Do not place the cord near a heated surface.
» Do not operate this product with a damaged cord or plug. Discard the product or return to an authorized service facility for examination and/or repair.
» Never use the power cord to pick up, carry, drag, pull, or lift the Therapure® 540 air purifier. Do not pull the cord against or around sharp corners and edges. This could result in injury to the user or damage to the cord.
» Always remove the plug from its power outlet by holding onto the plug itself and pulling gently.
» Never pull on the cord itself to unplug it from its power outlet.
» Use care when operating the Therapure® 540 air purifier by keeping all foreign objects, fingers, body parts, hair, loose clothing and jewelry away from openings.
» Never touch the Therapure® 540 air purifier or its plug when your hands are wet.
» The Therapure® 540 air purifier is an electrical appliance. Adult supervision is required when operating the Therapure® 540 in the presence of children.
» To reduce the risk of fire or electric shock, do not use this air purifier with any solid-state speed control devices.

IMPORTANT WARNINGS

UV Lamp Notice

UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision. Never look directly at the UV lamp while it is illuminated; doing so could cause loss of vision! Only view illumination through the window at the front of the unit. To prevent exposure to
ultraviolet light, disconnect the power to the unit before servicing any part of the Therapure® 540 air purifier.

UV Lamp Disposal

If the UV lamp breaks, turn off the unit. Do not operate the unit with a broken lamp. Do not use a vacuum to clean up breakage. Sweep debris into a plastic bag and dispose of properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of old lamp(s). To order a replacement lamp, call 1.800.875.8577 or go to www.envionproducts.com.

Mercury Notice

Because the Therapure® 540 contains a light bulb and light bulbs contain mercury, Envion is required to provide the following warning:

WARNING: This product contains mercury, a chemical known to the State of California to cause birth defects or other reproductive harm.

Do not place your used lamp(s) in the trash. Disposal of any item containing mercury must be in accordance with any hazardous waste disposal or recycling laws and regulations of your state.

PRODUCT BENEFITS

» Triple action purification:

  1. Permanent HEPA-type Filter.
  2. UV lamp.
  3. Photo catalyst filter.
    » 3 speed fan setting–lets you select the desired cleaning level.
    » 24-hour timer for automatic power off.
    » Night mode to dim the control panel light when you sleep
    » Clean filter indicator.

MAIN PARTS

  1. Locking Latch
  2. Air Inlet Grill
  3. Permanent HEPA-type Filter
  4. UV Lamp Cover
  5. Control Panel: Time, On/Off, Speed, UV/VOC and Night Mode
  6. UV Indicator Light Bar: Lights up when UV feature is turned ON
  7. Air Outlet Grill
  8. UV Lamp

OPERATING THE THERAPURE® TPP540

Before using the Therapure® 540 air purifier, please read the following important information.

Electrical Ratings:

  • • 120V Setting: 120Vac, 60 Hz
  • • Power consumption: 55 watts (0.45 ampere) at high fan speed,
  • • 3 watt UV light bulb
  • • Net weight: 9.5 lbs
  • • Dimension (L x W x H): 8.7” x 7.3” x 25.2”

Replacement Parts:

Lamp – TPP2400
Filter – TPP440F

Locate a level surface on which to place the Therapure® 540 air purifier near a 120V outlet (follow warnings in the “SAFETY INSTRUCTIONS”
and “IMPORTANT WARNINGS” sections of this manual). Position your Therapure® 540 at least one foot (12 inches) from the wall. Plug in the unit.

Before using the Therapure® 540 air purifier, please read the following important information.

Safety

  1. Do not place near fans.
  2. Keep both sides of the unit at least 1 foot away from a wall.
  3. Do not place the unit near curtains.
  4. Placing the unit close to the source of air pollution is an effective way to improve indoor air quality.
1
2
3
4

Note:
DO NOT run the Therapure® 540 with a broken filter. Replace the filter if the filter has a tear or a hole in it.

If the filter is damaged or needs replacement, please visit the Therapure® website at www.envionproducts.com to order for a replacement filter. Or call 1.800.875.8577.

CONTROLS/SETTINGS:

Power Control – To operate the Therapure® 540 air purifier, press the ON/OFF button to turn on the air purifier. Press the button again to turn the unit off.
Timer Control – The Therapure® 540 air purifier can be programmed to turn off after a preset amount of time. Press the “TIME” button to program the timer. Each press will add one hour up to a total of 24 hours. Keeping the button pressed will automatically increase to 24 hours, 1 hour at a time, after that it will turn back to off.
Fan Speed Control – The Therapure® 540 has three different speeds of cleaning, LOW, MED and HI. Press “SPEED” button to cycle the settings and select the fan speed you desire. The speed state will be shown on the LED display.
Clean Filter Indicator Light – The Therapure® 540 Clean Filter Indicator Light will turn on each time the filter needs to be cleaned. To reset the filter indicator, press the TIME and the ON/OFF buttons together for 3 seconds. The CLEAN FILTER light will flash 3 times and then turn off completely, indicating the unit has been reset.
Night Mode – If the UV light bar is too bright, press the “Night Mode” button to turn off the UV light bar feature, and the lighted display. The ON/OFF indicator, however, will remain lit. The night mode only turns off UV light bar not the actual UV feature.
UV Control – Press the UV/ VOC control button “UV/VOC” to turn on the UV lamp and the photocatalyst filter.

CLEANING & MAINTENANCE

Keep the Therapure®540 functioning properly by cleaning the permanent HEPA-type filter every four weeks of use. More frequent cleaning will be necessary if the unit is located in an area with a high level of airborne contaminants (excessive amounts of smoke, pet dander, etc.).

Exposing the Therapure® 540 to candle/oil/fireplace soot and smoke is not recommended and will require more frequent cleaning.

NOTE: Always make sure the Therapure® 540 is turned off and unplugged before cleaning.
» Vacuuming will restore performance of the permanent HEPA-type Filter. However, the filter may appear stained. This is normal and does not affect performance in any way.
» Do not use water or any household cleaners or detergents to clean the permanent HEPA-type Filter.
» The inlet grill may be cleaned (after unit is turned off and unplugged) with a vacuum or a slightly damp cloth.

Cleaning the permanent HEPA-type Filter

  1. Release the inlet grill by pressing on the locking latch (see diagram of Main Parts).
  2. Remove the inlet grill from the unit as shown below.
  3. Grasp the left and right frames of the permanent HEPA-type Filter through the indentations on the sides of the filter enclosure and remove the filter.
  4. To clean the permanent HEPA-type Filter, use the brush or crevice attachment with a vacuum cleaner. Run the attachment along the inlet and outlet side of the filter, cleaning between the crevices as much as possible. Do not use water or any household cleaners or detergents to clean the permanent HEPA-type Filter.
  5. Once the permanent HEPA-type Filter has been cleaned and checked for any possible damage, replace the filter back in the reverse direction described here. Plug in the unit and hold down Time + Power On button for 3 seconds. The clean filter light will go off and your cleaning maintenance is done.
1
2
3
4

Cleaning External Surfaces

  1. Turn off and unplug unit.
  2. Use a washcloth slightly dampened with a little water and dishwashing soap to wipe the outer case surfaces.
  3. Do not allow water to slip into the internal parts as this could damage your unit and result in electrical shock and injury to you.
  4. Allow the unit to thoroughly dry before use.

UV Lamp

The lifetime of the UV lamp is up to 12 months of continuous, effective operation. After this time, the bulb may remain illuminated, but its effectiveness is greatly reduced. For maximum effectiveness, please replace the UV bulb annually. If the lamp stops functioning or needs
replacement, please visit our web site at www.envionproducts.com to order a replacement lamp. Or call 1.800.875.8577.

Caution:

• Do not touch the glass part of the lamp. Oil from fingertips will decrease the effectiveness of the lamp.
• Never operate the unit without a filter or with a damaged filter. UV lamp cover must be installed at all times. The UV light from the UV
lamp will result in severe damage to eyes and could cause blindness.

UV Lamp Notice Warning:

UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision. Never look directly at the UV lamp while it is
illuminated-doing so could cause loss of vision!

Before replacing the UV lamp, make sure the Therapure® 540 air purifier is turned off and unplugged. Let the lamp cool down for 5 minutes before replacing it.

Replacing the UV Lamp:

  1. Release the inlet grill by pressing on the locking latch.
  2. Grasp the left and right frames of the permanent HEPA-type filter through the indentations on the sides of the filter enclosure and remove filter.
  3. Remove the two bolts used to fix the UV lamp cover and remove the cover out from the unit then unscrew the old UV lamp from the lamp base of the unit.
  4. Install the new UV lamp into the lamp base of the unit.
  5. Install the UV lamp cover with the two bolts on the unit.
  6. Install the inlet grill on the unit.
1
2
3
4
5
6

TROUBLESHOOTING

PROBLEM REASONSOLUTION
Unit will not operate.Power button has not been turned on.Press the Power button
Unit is unplugged.Check to ensure unit is plugged in.
The inlet grill has not been installed & locked into place.Check to make sure filter and inlet grill is properly installed & locked into place.
Reduced airflow or
poor filtering.
The inlet or outlet grill may be blocked.Check to ensure nothing is blocking air inlet & air outlet.
Permanent filter may be clogged.Check & clean filter, if necessary.

READ ALSO: Coway Air Purifier AP-1512HH & AP-1512HH(W) User’s manual

ONE-YEAR LIMITED WARRANTY

Your Therapure® 540 air purifier is warranted to be free from defects in materials and workmanship for one year from the original purchase date. Should the product have a defect in materials or workmanship, we will repair or replace it without charge to you (a shipping and processing fee will apply). To obtain service under warranty, simply call our customer service center toll-free at 800.875.8577.

This warranty does not cover damage caused by accident, misuse or any use other than as intended and described in this product manual, or damage resulting from failure to maintain and clean this product as specified in this product manual. This warranty applies only to the original purchaser of the Therapure® 540 air purifier.

ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD, AND NO WARRANTIES, WHETHER EXPRESS OR IMPLIED, WILL APPLY AFTER THIS PERIOD.

Some states do not allow limitations on the duration of implied warranties, so the above limitation may not apply to you. While this warranty gives you specific legal rights, you may also have other rights which may vary from state to state.

Contact Info for Warranty Service:
Therapure® by Envion LLC
P.O. Box 9159 | Van Nuys, CA | 91409-8291
1.800.875.8577 | www.envionproducts.com
© 2015 Envion, LLC. All Rights Reserved. Patents pending.

The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model’s CADR for dust and the electrical energy it consumes, or CADR/Watt.

This product earned the energy star by meeting strict energy efficiency guidelines set by the US EPA does not endorse any manufacture claims of healthier indoor air from the use of this product.

You can download the PDF version of the TPP540 uv air purifier User’s Manual here.