Weather

Package Contents

  1. Display
  2. Power Adapter
  3. Instruction Manual

This product requires an Acurite 3-in-1 Weather Sensor (sold separately) to be operational.

PRODUCT REGISTRATION
Register online to receive 1-year warranty protection www.AcuRite.com Questions? Contact Customer Support at (877) 221-1252 or visit www.AcuRite.com.

Features & Benefits

FRONT OF DISPLAY

  1. Current Outdoor: Temperature Arrow icon indicates the direction the temperature is trending.
  2. Seasonal Information: Heat Index calculation displays when temperature is 80°F (27°C) or higher. Dew Point calculation displays when temperature is 79°F (26°C) or below Wind chill calculation displays when temperature is 40°F (4°C) or lower.
  3. Current Wind Speed
  4. Average Wind Speed: Average wind speed over the past 2 minutes.
  5. Learning Mode Icon: Disappears after weather forecast self-calibration is complete.
  6. 12 to 24 Hour Weather Forecast: Self-Calibrating Forecasting pulls data from your sensor to generate your personal forecast.
  7. Storm Indicator: Indicates when barometric pressure drops.
  8. Humidity Level Indicator: Indicates a high or low indoor humidity level.
  9. Current Indoor Temperature: Arrow icon indicates the direction the temperature is trending.
  10. TODAY Icon: Indicates today’s high/low records are displayed.
  11. Moon Phase
  12. ALL-TIME Icon: Indicates all-time records are displayed.
  13. Button: For momentary backlight and dimmer settings.
  14. AUTO DIM Indicator: Indicates display is in auto-dimming brightness mode
  15. Display Low Battery Indicator
  16. Date
  17. Intel-Time® Clock: Automatically updates itself for Daylight Saving Time.
  18. Current Indoor Humidity: Arrow icon indicates the direction the humidity is trending.
  19. Barometric Pressure: Arrow icon indicates the direction the pressure is trending.
  20. Peak Wind Speed: Highest speed from past 60 minutes.
  21. Current Outdoor Humidity: Arrow icon indicates the direction the humidity is trending.
  22. Outdoor Sensor Signal Strength
  23. Sensor Low Battery Indicator

BACK OF DISPLAY

1.Button

: For setup preferences.

2. Button

: For setup preferences.

3. Button

: For setup preferences.

4.Button

: Press to access all-time high and low records.

5.Intelli-Time® Battery Compartment

6. Plug-in for Power Adapter

7. Power Adapter

8.Backup Battery Compartment

9. Reset Button: Full reset to factory defaults.

10. A-B-C Switch: ID code that must match sensor’s A-B-C switch to ensure units synchronize.

11. Battery Compartment Cover (not shown)

Display Setup

1 Set the A-B-C Switch
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must
select the same letter choices for both the display and the sensor in order for the units to synchronize.
2 Install or Replace Backup Batteries (optional)

  1. Remove the battery compartment cover.
  2. Insert 3 x AAA alkaline batteries into the battery compartment, as shown Follow the polarity
    (+/-) diagram in the battery compartment.
  3. Replace the battery cover.

3 Plug in Power Adapter: For the best performance, plug in the power adapter as the main power source for this product.

IMPORTANT: ABC Batteries are a backup power source to preserve records in the event of a power outage. Power adapter is recommended as the primary power source to enjoy the full functionality of this product.

PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment that will not be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries {alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.

Set the Time, Date & Units

Press the

button, located on the back of the display, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display.
To adjust the currently selected (flashing) item, press and release the

or

buttons (press and HOLD to Fast adjust).

To save your adjustments, press and release the

button again to adjust the next preference. The preference set order is as follows:
TIME ZONE (EST CST MST PST AKT HAT AST)
DST (Daylight Saving Time ON or OFF) *
CLOCK HOUR
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
TEMPERATURE UNITS (°F or °C)
PRESSURE UNITS (in Hg or h Pa)
WIND UNITS (MPH or KPH)

  • IF you live in an area that observes Daylight Saving Time, DST should be set to ON, even if it is not
    currently Daylight Saving Time.


You will automatically exit SET MODE if no buttons are pressed for 10 seconds. Enter setup mode at any time by pressing the

button.

Display Backlight Settings

This weather station’s color display features three different lighting settings: High (100%) brightness, Medium (60%) brightness and Low (30%) brightness.
Using battery power alone, the backlight is available momentarily for 10 seconds by pressing the


button.
When display is powered with the power adapter, backlight remains on at 100% brightness. Press


button once to dim to 60% brightness; press again to dim to 30%, press a 3rd time to enter “AUTO DIM” mode. AUTO DIM appears below time.

AUTO DIM MODE: Automatically adjusts display brightness based on time of day & year. 
MARCH 11- NOVEMBER 4 6:00 a.m. – 9:00 p.m. = 100% brightness 
9:01 p.m. – 5:59 a.m.= 30% brightness 
NOVEMBER 5 – MARCH 10 7:30 a.m. – 7:00 p.m.= 100% brightness 
7:01 p.m. – 7:29 a.m. = 30% brightness 

Placement for Maximum Accuracy

Acurite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display and the sensor are critical to the accuracy and performance of this product.

Display Placement

Place the display in a dry area free of dirt and dust. To ensure accurate temperature measurement, place out of direct sunlight and away from heat sources or vents. Display stands upright for tabletop use.

Important Placement Guidelines

Display and sensor must be within 330 feet (100 m) of each other.

MAXIMIZE WIRELESS RANGE

Place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.

PREVENT WIRELESS INTERFERENCE

Place both units at least 3 feet {.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).

OPERATION

Using The Weather Center

Learning Mode

Self-Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period (called Learning Mode} to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction.

Weather Forecast

AcuRite’s patented Self-Calibrating Forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard. It generates a forecast with pinpoint accuracy – personalized for your exact location.

View the complete list of icons at www.AcuRite.com/acurite-icons

Barometric Pressure

Subtle variations in barometric pressure greatly impact the weather. This weather center displays the current pressure with an arrow icon to indicate the direction the pressure is trending (FALLING, STEADY, or RISING).

Moon Phase

Track the phases of the moon, conveyed through simple lunar phase icons:

NEW
WAXING CRESCENT
1ST QUARTER
FULL
3RD QUARTER
WANING CRESCENT

High & Low Records

Today’s high and low records are displayed for indoor and outdoor temperature, humidity and wind speed. Today’s records automatically clear at 12:00am midnight every day.
To manually clear all of today’s LOW recorded values, press and hold the

button for 2 seconds. Dashes display to confirm you have cleared the LOW records.
To manually clear all of today’s HIGH recorded values, press and hold the

button for 2 seconds.
Dashes display to confirm you have cleared the HIGH records.
Press the

button to cycle through the all-time high and low recorded values (one record is shown at a time) for outdoor and indoor temperature and humidity. Located near the clock, a date and time stamp are shown for when each value was recorded. You will automatically exit all-time records if no buttons are pressed for 5 seconds.
To manually clear an all-time LOW record, press and hold the

button for 2 seconds while viewing the record you wish to clear. Dashes display to confirm you have cleared the record.

To manually clear an all-time HIGH record, press and hold the

button for 2 seconds while viewing the record you wish to clear. Dashes display to confirm you have cleared the record.

Troubleshooting

Problem Possible Solution 
No outdoor sensor  reception  T111I  no bars   • Relocate the display and/or the 3-in-1 sensor.  The units must be within 330 ft (100 m) of each other.  • Make sure both units are placed at least 3 feet  (.9 m) away from electronics that may interfere with  the wireless communication (such as TVs, microwaves,  computers, etc).  • Use standard alkaline batteries (or lithium batteries in  sensor when temperature is below -20ºC/-4ºF). Do not  use heavy duty or rechargeable batteries.  NOTE: It may take a few minutes for display and  sensor to synchronize after batteries are replaced.  • Synchronize the units:  1. Bring both the sensor and display indoors and  remove power adapter/batteries from each. 2. Reinstall batteries in outdoor sensor.  3. Reinstall power adapter in display.  4. Let the units sit within a couple feet of each other  for a few minutes to gain a strong connection. 
Outdoor  temperature  is flashing or   showing dashes Flashing of the outdoor temperature may be an indication of  wireless interference:  • Make sure the A-B-C switch in the battery compartments of  both the display unit and sensor are switched to the same  letter. You may choose A, B or C; but both units must match  to sync up. Sometimes changing to a different channel can  help. 
Inaccurate forecast • Weather Forecast icon predicts conditions for the next 12  to 24 hours, not current conditions.  • Has Learning Mode icon disappeared from the display  unit? Learning Mode must complete before forecast and  pressure will be accurate.  • Allow unit to run continuously for 33 days. Battery removal  or resetting the display unit will restart Learning Mode.  After 14 days, forecast should be fairly accurate, however  Learning Mode calibrates for a total of 33 days. 
Inaccurate  temperature or    humidity • Make sure both the display unit and 3-in-1 sensor are  placed away from any heat sources or vents • Make sure both units are positioned away from moisture  sources  • Make sure 3-in-1 sensor is mounted at least 5 ft off of  the ground.  • Calibrate indoor and outdoor temperature and humidity   
Inaccurate wind  readings • What is wind reading being compared to? Pro weather  stations are typically mounted at 30 ft high or more. Make  sure to compare data using a sensor positioned at the  same mounting height.  • Check location of the sensor. Ensure it’s mounted a  minimum of 5 ft in the air with no obstructions around it  (within several feet).  •Ensure wind cups are spinning freely. If they hesitate or stop  try lubricating with graphite powder or spray lubricant. 
Display screen  not working • Check that the power adapter is plugged into the display  and an electrical outlet.  • Check that the batteries are installed correctly.  Batteries may need to be replaced.  • Reset the display by pressing the RESET button, located on  the back of the display unit in the battery compartment.  Date and time will need to be entered after a reset. 
Inaccurate barometric  pressure It may take up to 14 days for the pressure to calibrate to  your location. 
The unit lost power  or batteries were  changed and the  time is not correct The Intelli-Time battery needs to be replaced . Once the new battery is installed,  time and date will need to be set manually. 

If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call (877) 221-1252 for assistance.

Care & Maintenance

Display Care

Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air.

Calibration

The indoor / outdoor temperature and humidity readings, and barometric pressure can be calibrated on the display to improve accuracy. Calibration can improve accuracy when sensor placement or environmental factors impact the data accuracy.

  1. To access calibration mode, press AND HOLD the

and

buttons simultaneously for at least 5 seconds.

To adjust the currently selected (flashing) item, press and release the

or

buttons to calibrate the data value higher or lower from the actual reading.

To save your adjustments, press and release the

button to adjust the next preference. The


icon will remain illuminated next to calibrated values.

The preference set order is as follows:
OUTDOOR TEMPERATURE
OUTDOOR HUMIDITY
INDOOR TEMPERATURE
INDOOR HUMIDITY
BAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)
To change from AUTO to MANUAL pressure mode and vice versa, press AND HOLD the

button for at least 10 seconds. The display indicates the current pressure mode selected, “AUTO” or “MANUAL”.
After 20 seconds of inactivity, the display will save the adjustments and exit calibration mode. Note: Calibrations will be erased if the display is reset or if batteries are removed and the power adapter is unplugged.

Replace Intelli-Time® Clock Battery

Intelli-Time technology is powered by a pre-installed coin-cell battery that stores the time and date settings. The battery has a shelf life of several years. To replace the Intelli-Time battery:

  1. Locate the coin cell battery compartment door on the back of the display. Unscrew and remove the compartment cover.
  2. Insert 1 x CR2032 coin cell battery into the battery compartment, as shown. Install battery with “+” positive terminal facing OUT.
  3. Screw in the battery cover.


WARNING: THIS PRODUCT CONTAINS A BUTTON-CELL BATTERY. IF SWALLOWED, IT COULD CAUSE SEVERE INJURY OR DEATH IN JUST 2 HOURS. 2 SEEK MEDICAL ATTENTION IMMEDIATELY IF INGESTED. POISON FOIBON

Specifications

TEMPERATURE RANGE C º C to 70 º F; -40 º F to 158 º Outdoor: -40 
C º C to 50 º F; 0 º F to 122 º Indoor: 32
HUMIDITY RANGE Outdoor: 1% to 99% 
Indoor: 1% to 99% 
WIND SPEED 0 to 99 mph; 0 to 159 kph 
WIRELESS RANGE 330 ft / 100 m depending on home construction materials 
OPERATING FREQUENCY 433 mhz 

FCC Information  

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions: 

1- This device may NOT cause harmful interference, and 

2- This device must accept any interference received, including interference that may cause undesired operation. WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the  user’s authority to operate the equipment. 

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC  – rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equip ment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may  cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular  installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning  the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  •   Reorient or relocate the receiving antenna.
  •  Increase the separation between the equipment and the receiver.
  •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  •   Consult the dealer or an experienced radio/TV technician for help. 

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.  Such modifications could void the user authority to operate the equipment. 

This device complies with Industry Canada licence-exempt RSS standard(s). 

Operation is subject to the following two conditions: 

  (1) This device may not cause interference, and

  (2) This device must accept any interference received, including interference that may cause undesired operation of the device.

Customer support
Acurite customer support is committed to providing you with best in class service. For assistance, please have the model number of this product available and contact us in any of the following ways:

(877) 221 1252

  • Visit us at www.AcuRite.com
  • Installation videos
  • Instruction manuals
  • Replacement parts
  • Register your product
  • Support user forum
  • Submit feedback and ideas

Limited 1-Year Warranty

AcuRite is a wholly owned subsidiary of Chaney Instrument Company. For purchases of AcuRite products, AcuRite provides the benefits and services set BS forth herein. For purchases of Chaney products, Chaney provides the benefits and services set forth herein.

We warrant that all products we manufacture under this warranty are of good material and workmanship and, when properly installed and operated, will be free of defects for a period of one year from the date of purchase.
Any product which, under normal use and service, is proven breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by us, and at our sole option, be repaired or replaced by us. Transportation costs and charges for returned goods shall be paid for by the purchaser. We hereby disclaim all responsibility for such transportation costs and charges. This warranty will not be breached, and we will give no credit for products which have received normal wear and tear not affecting the functionality of the product, been damaged (inducing by acts of nature}, tampered, abused, improperly installed, or repaired or altered by others than our authorized representatives.
Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). If we determine that repair or replacement is not feasible, we may, at our option, refund the amount of the original purchase price.
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY FOR THE PRODUCTS AND IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE
We expressly disclaim all liability for special, consequential, or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
We further disclaim liability from personal injury relating to our products to the extent permitted by law. By acceptance of any of our products, the purchaser assumes air for the consequences arising from their use or misuse. No person, firm or corporation is authorized to bind us to any other obligation or liability in connection with the sale of our products. Furthermore, no person, firm or corporation is
authorized to modify or waive the terms of this warranty unless done in writing and signed by a duly authorized agent of ours.
In no case shall our liability for any claim relating to our products, your purchase or your use thereof, exceed the original purchase price paid for the product.

Applicability of Policy

This Return, Refund, and Warranty Policy applies only to purchases made in the United States and Canada. For purchases made in a country other than the United States or Canada, please consult the policies applicable to the country in which you made your purchase.
Additionally, this Policy applies only to the original purchaser of our products. We cannot and do not offer any return, refund, or warranty services if you buy products used or from resale sites such as eBay or Craigslist.

Governing Law

This Return, Refund, and Warranty Policy is governed by the laws of the United States and the State of Wisconsin. Any dispute relating to this Policy shall be brought exclusively in the federal or State courts having jurisdiction in Walworth County, wane, end purchaser consents to jurisdiction within the State of Wisconsin.

ACURITE

Weather Stations
Temperature & Humidity
Weather Alert Radio
Kitchen Thermometers & Timers
Clocks


It’s More than Accurate, it’s ACLDRITE. AcuRite offers an extensive assortment of precision instruments, designed to provide you with
information you can depend on to Plan your day with confidence.
www.AcuRite.com
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy- rights are the property of their respective owners. AcuRite uses patented technology.

Visit www.AcuRite.com/patents for details. Printed in China 06020 INST 022117

You can download the PDF version of the Acurite instruction manual Display for 3-in-1 Weather Sensor model 06020 User’s Manaul here.